§ 3-4-608. Appendix.


Latest version.
  • Table 1: Maximum Number of Portable Sanitation Units at Construction Sites

    Number of Workers* Minimum Number of Units Serviced Weekly**
    20 or less 1 toilet per 20 workers
    21 or more 1 additional toilet per 40 workers
    200 or more 1 additional toilet per 50 workers
    Source: 29 CFR 1926.51 OSHA Regulations for Toilets at Construction Sites

     

    * The number of potable sanitation units required shall be determined by the maximum number of workers present on a regular eight-hour shift. Shifts lasting longer than eight (8) hours (forty-hour work week) should double the number of portable sanitation units.

    ** "Servicing" refers to the emptying of waste and the cleaning of the portable sanitation unit.

    Table 2: Portable Sanitation Units for Special Events Planning

    Average Crowd Size Average Hours at the Event*
    1 2 3 4 5 6 7 8 9 10
    500 2 4 4 5 6 7 9 9 10 12
    1,000 4 6 8 8 9 9 11 12 13 13
    2,000 5 6 9 12 14 16 18 20 23 25
    3,000 6 9 12 16 20 24 26 30 34 38
    4,000 8 13 16 22 25 30 35 40 45 50
    5,000 12 15 20 25 31 38 44 50 56 63
    10,000 15 25 38 50 63 75 88 100 113 125
    15,000 20 38 56 75 94 113 131 150 169 188
    20,000 25 50 75 100 125 150 175 200 225 250
    25,000 38 69 99 130 160 191 221 252 282 313
    30,000 46 82 119 156 192 229 266 302 339 376
    35,000 53 96 139 181 224 267 310 352 395 438
    40,000 61 109 153 207 256 305 354 403 452 501
    45,000 68 123 178 233 288 343 398 453 508 563
    50,000 76 137 198 259 320 381 442 503 564 626
    55,000 83 150 217 285 352 419 486 554 621 688
    60,000 91 164 237 311 384 457 531 604 677 751
    65,000 98 177 257 336 416 495 475 654 734 813
    70,000 106 191 277 362 448 533 619 704 790 876
    75,000 113 205 296 388 480 571 663 755 846 938
    80,000 121 218 316 414 512 609 707 805 903 1,001
    85,000 128 232 336 440 544 647 751 855 959 1,063
    90,000 136 246 356 466 576 686 796 906 1,016 1,126
    95,000 143 259 375 491 607 724 840 956 1,072 1,188
    100,000 151 273 395 517 639 762 884 1,006 1,128 1,251

     

    Based on "Portable Restroom Requirements at Special Events and Crowd Gatherings" Center for Business and Industrial Studies, University of Missouri-St. Louis

    Determine the appropriate potable sanitation units needed from the table above.

    For each sewered toilet available onsite, subtract one (1) from the previously calculated number.

    If alcoholic beverages are to be served, add twenty-five (25) percent to the base number.

    For peak crowd numbers that fall between chart numbers, round up to the next base number.

    Units shall be provided in accordance with the Georgia Accessibility Code following state or local requirements.

    Table based on units being serviced daily.

( Ord. No. 16-04, 4-5-16 )